Descrizione
The SF23092A axial fan (P/N N2092HSL) is designed for forced cooling of electronic devices and switchboards powered from the mains. Thanks to the 220240V AC power supply, it is suitable for applications where auxiliary DC voltage is not available and where stable air flow is required in a compact format of 92×92×25 mm.
Technical specifications
Model: SF23092A (P/N N2092HSL)
Type: axial AC fan
Supply voltage: AC 220-240V
Working voltage: 220V (range 185-245V)
Mains frequency: 50/60 Hz
Dimensions: 92 × 92 × 25 mm
Power consumption: 13/11 W (50/60 Hz)
Speed: 2250/2750 rpm (50/60 Hz)
Airflow: 29/36 CFM
Noise level: 32/37 dB(A)
Weight: 280g
Bearings: double balls
Frame: aluminum alloy (cast), black painted, corrosion and moisture resistance
Impeller: injection-molded, PBT + 30% glass fiber, VO (self-extinguishing version)
Winding insulation: enamelled wire, temperature class B (120 °C)
Insulation resistance:> 500 M
Electrical strength test: 1500 V / 1 min, leakage current 0.5 mA
Ambient temperature (according to documents): -50 °C
Functions and features
Power supply directly from AC 220-240 V for standard industrial installations
Double ball bearings for long-term operation and higher mechanical resistance
Compact size of 92×92×25 mm for installation in control cabinets and devices with limited space
Aluminum alloy frame with surface treatment for increased resistance to moisture and corrosion
Blade material PBT with glass fiber and self-extinguishing classification (VO according to documents)
Ideal for
Cooling of switchboards, power supplies and industrial control systems
Ventilation of electronic cabinets and mains-powered instrument boxes
Cooling of power elements, converters, UPS and laboratory equipment
General forced air flow in technical applications
Package contents
1× axial fan SF23092A (P/N N2092HSL)
Why choose this product?
Verifiable parameters from the documents: dimensions 92×92×25 mm, AC 220240 V, 50/60 Hz, flow rate and noise level
AC design eliminates the need for a separate DC power supply
The construction with an aluminum frame and ball bearings is suitable for continuous technical operation
The electrical strength and insulation parameters specified by the manufacturer support use in network applications
Installation and operating instructions
During installation, observe the direction of air flow according to the orientation of the fan in the device.
Ensure sufficient conductor cross-section and mechanical relief of the supply to avoid stress on the terminals/terminals.
For stable operation, respect the specified supply voltage range and mains frequency of 50/60 Hz.
In dusty environments, we recommend using a filter grid and regular maintenance to maintain flow.
Safety notice
The product is powered by AC 220240 V. Installation and service should only be carried out with the power supply disconnected and in accordance with applicable standards.
Do not touch rotating parts; use a suitable protective grille during assembly if the fan is accessible.
Do not use the fan if the power cord, frame or impeller is damaged.





Recensioni